General | PKT-300P | PKT-300LFP | |
---|---|---|---|
Frequency Range | 450-470 MHz | 462.550 - 467.7125 MHz Preset 15 of GMRS channels (Selectable from 22 GMRS/FRS channels) |
|
Number of Channels | 16 | ||
Channel Spacing | 12.5 kHz | ||
Battery Life (5-5-90 duty cycle) with KNB-81L (3.6V/2200mAh) |
Approx. 14 hours (Battery saver off) Approx. 18 hours (Battery saver on) |
||
Operating Temperature Range* | -10°C ~ +60°C (-14°F ~ +140°F) | ||
Frequency Stability | ±2.5ppm | ||
Dimensions | Radio with KNB-81L | (W x H x D) Projections Not Included 1.97 x 3.86 x 1.06 in (50 x 98 x 27 mm) |
|
Weight | Radio with KNB-81L | 4.94 oz (140 g) | |
ISED ID | 282F-523500 | 282F-523501 |
Receiver | PKT-300P | PKT-300LFP |
---|---|---|
Sensitivity (12 dB SINAD) | 0.28 μV | |
Selectivity | 60 dB | |
Intermodulation Distortion | 60 dB | |
Spurious Response | 70 dB | |
Audio Output Power | 100 mW |
Transmitter | PKT-300P | PKT-300LFP | |
---|---|---|---|
RF Power Output | High / Low | 2.0 / 0.5 W (ERP) | |
Spurious Response | -36 dBm ≤ 1 GHz, -30 dBm > 1 GHz | ||
FM Hum & Noise | 50 dB | ||
Audio Distortion | Less than 5% | ||
Type of Emission | 11K0F3E |
*Operating temperature specification for a Li-ion battery is 14°F to +140°F (-10°C to +60°C)
Specifications shown are typical and subject to change without notice, due to advancements in technology
Details and timing of firmware and software updates are subject to change without notice.
Analog measurements made per TIA603. Specifications are measured according to applicable standards.
ProTalk® is a registered trademark of JVCKENWOOD Corporation.
All other trademarks are the property of their respective holders.
MIL Standard | MIL 810C Methods/Procedures | MIL 810D Methods/Procedures | MIL 810E Methods/Procedures | MIL 810F Methods/Procedures | MIL 810G Methods/Procedures | MIL 810H Methods/Procedures |
---|---|---|---|---|---|---|
Low Pressure | 500.1/Procedure I | 500.2/Procedure I, II | 500.3/Procedure I, II | 500.4/Procedure I, II | 500.5/Procedure I, II | 500.6/Procedure I, II |
High Temperature | 501.1/Procedure I, II | 501.2/Procedure I, II | 501.3/Procedure I, II | 501.4/Procedure I, II | 501.5/Procedure I, II | 501.7/Procedure I, II |
Low Temperature | 502.1/Procedure I | 502.2/Procedure I, II | 502.3/Procedure I, II | 502.4/Procedure I, II | 502.5/Procedure I, II | 502.7/Procedure I, II |
Temperature Shock | 503.1/Procedure I | 503.2/Procedure I | 503.3/Procedure I | 503.4/Procedure I, II | 503.5/Procedure I | 503.7/Procedure I |
Solar Radiation | 505.1/Procedure I | 505.2/Procedure I | 505.3/Procedure I | 505.4/Procedure I | 505.5/Procedure I | 505.7/Procedure I |
Humidity | 507.1/Procedure I, II | 507.2/Procedure II, III | 507.3/Procedure II, III | 507.4 | 507.5/Prcedure II | 507.6/Prcedure II |
Vibration | 514.2/Procedure VIII, X | 514.3/Procedure I | 514.4/Procedure I | 514.5/Procedure I | 514.6/Procedure I | 514.8/Procedure I |
Shock | 516.2/Procedure I, II, V | 516.3/Procedure I, IV | 516.4/Procedure I, IV | 516.5/Procedure I, IV | 516.6/Procedure I, IV | 516.8/Procedure I, IV |
International Protection Standard | ||||||
Dust & Water Protection | IP52 Audio accessory cap must be used to meet IP52 specification. |